Artículo: AMZ-B08YNRKXBG

Taidacent

Taidacent Frequency Signal Converter RS485 to 0~10V Analog Voltage Control Output Converter Modbus to Analog Converter with Manual Adjustment (12V)

Style:

12V

12V

24V

Disponibilidad
En stock
Peso con empaque
0.83 kg
Devolución
Condición
Nuevo
Producto de
Amazon

Sobre este producto
  • Board size: 92mm*36mm*58mm
  • Working voltage: DC 12V and 24V two kinds, the default delivery is DC 12V
  • Input: Add: You can connect the external button to manually adjust and increase the analog output
  • Minus: You can connect the external button to manually adjust to reduce the analog output
  • DC+: Positive power supply; DC-: negative pole of power supply
$155,09
44% OFF
$86,16

IMPORT EASILY

By purchasing this product you can deduct VAT with your RUT number

$155,09
44% OFF
$86,16

Difiere a 3 y 6 meses sin intereses con Diners, Discover y Titanium

Envío gratis
Llega en 12 a 16 días hábiles
Con envío
Tienes garantia de entrega
Este producto viaja de USA a tus manos en
Medios de pago Tarjetas de Débito, Crédito y Deuna

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

Parameter Board size: 92mm*36mm*58mm Working voltage: DC 12V and 24V two kinds, the default delivery is DC 12V Input: Add: You can connect the external button to manually adjust and increase the analog output Minus: You can connect the external button to manually adjust to reduce the analog output DC+: Positive power supply DC-: negative pole of power supply Output: 12V+: the positive pole of the analog power supply, a power supply is required for front and rear isolation. If the same power supply is used, it will not have the isolation effect. Vout: analog analog output, output 0-10V analog signal voltage to GND GND: The negative pole of the analog power supply. It is necessary to provide a power supply if the front and back are isolated. If the same power supply is used, the isolation will not be achieved. Protocol: standard modbus-RTU protocol Communication: RS485 interface Function Description Mainly used for inverter control, equipment that needs 0~10V input control The plus and minus input can be connected to an external button to manually adjust the 0~10V output voltage, as shown in the label diagram below Protocol description: (Modbus-RTU) 1. Communication parameters: 9600b/s, no parity, 8 data, 1 stop 2. The set value range is decimal 0-1000 (conversion hexadecimal is 0x0000 to 0x03e8) corresponding to the output voltage 0-10V. 3. The instructions are explained in detail as follows (in fact, the three instructions are relatively simple) a. Set the output voltage The host computer sends the command: (Set the output 10v as an example, where 03E8 represents the decimal system is 1000, that is, 10V) Module address 01 Function code 06 Register higher 20 Register low 01 High setting 03 Low setting E8 crc high D3 crc lower 74 Module returns: 01 06 20 01 03 E8 D3 74