FTVOGUE 2P Dual Power Automatic Transfer Switch 63A PC Level Infrequent Conversion Switch Dual Station Design ATS for Generators with DIN Rail Mount 50/60Hz (110VAC)
Style:
110VAC
Size:
110VAC
En stock
0.53 kg
No
Nuevo
Amazon
USA
- Spec: Item Type: Dual Power Automatic Transfer Switch Rated Current In: 63A Insulation Voltage Ui: 690VAC Grade: PC Frequency: 50/60Hz Standard: IEC60947-6 Rated Short Circuit Current Limit(RT16-00/63A): 50KA Package List: 1 x Dual Power Automatic Transfer Switch Note: Maintenance and inspection should be carried out by professionals. 1. To ensure the good performance of the ATS, the first maintenance and inspection should be conducted within 6 months of use. Subsequently, maintenance and inspection should be performed at least once a year. In harsh installation conditions, the frequency of maintenance and inspection should be increased. 2. Check for deformation and damage to electrical parts, and clean the surface. 3. Metal particles and local burning. , oxidation, and dust on the surface can result in poor , so manual operation and measurement of the necessary resistance should be performed. 4. If the ATS is damp or has not been used for a long time, dry before connecting the power. After removing dust, use a 500V megohmmeter to measure the insulation resistance of the normal power source and the AC power source. The insulation resistance, including the load side and both poles, should not be less than 10MQ when using live parts and metal plates.
IMPORT EASILY
By purchasing this product you can deduct VAT with your RUT number
Conoce más detalles
PREVENT POWER FAILURE: The main function of the automatic transfer switch is that when the main power supply(common power supply A) fails, the automatic transfer switch will automatically switch to the standby power supply(standby power supply B) to continue working(switching speed is less than 50 milliseconds), which can effectively solve the failure caused by power failure APPLICABLE CURRENT: The conversion switch is a PC level infrequent conversion switch, with dual station design(A is the common power supply, B is the standby power supply), suitable for AC 50‑60hz AC system TEMPERATURE RANGE: The operating temperature of the power transfer switch range from ‑5℃ to +40℃, and the average temperature within 24 hours should be lower than +35℃. The storage temperature ranges from ‑25℃ to +55℃, and can +70℃ in a short time(within 24 hours) INSTALLATION NOTE: When the ambient temperature is +40℃, the relative humidity of the installation site shall not exceed 50%. The lower the temperature, the higher the relative humidity. For example, when the average minimum temperature in the wettest month is +20℃, the monthly average maximum relative humidity for that month can 90%. Appropriate measures should be taken to prevent condensation due to temperature changes POLLUTION DESCRIPTION: The dual power transfer switch has a pollution level of 3 (conductive pollution, or dry non conductive pollution become conductive pollution due to condensation). The ATS can be installed vertically or horizontally in the cabinet