Artículo: AMZ-B000EOMS1G

Milwaukee Instruments MA9071 Oxygen Electrolyte Solution (230 ml)

Disponibilidad
En stock
Peso con empaque
0.53 kg
Devolución
No
Condición
Nuevo
Producto de
Amazon

Sobre este producto
  • For MW600 DISSOLVED OXYGEN METER
  • Package: Bottle
  • Size: 230 mL
  • Quantity: 1
  • Certificate of Analysis: No

Producto prohibido

Este producto no está disponible

Este producto viaja de USA a tus manos en
Medios de pago Tarjetas de Débito, Crédito y Deuna

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

Milwaukee Instruments MA9071 For MW600 DISSOLVED OXYGEN METERPackage: BottleSize: 230 mLQuantity: 1Certificate of Analysis: No Oxygen Electrolyte Solution The MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high-quality electrolyte solution is crucial to the performance of your dissolved oxygen probe. Design Features Precise formulationFactory mixed using reagent grade chemicals in a dedicated, temperature-controlled environment.TraceableA product labeled with product code, lot number and expiration date.SecureAir tight bottle with a tamper-proof seal. Use and Care “Open Air” Calibration Procedure for the MW600 Dissolved Oxygen Meter1. Remove the membraneTake the membrane off the end of the probe and dry the diode off.2. Zero out the displayConnect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screwdriver provided and through the access hole make the unit display read 0.0.3. Fill the membraneGo to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with the MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)4. Attach the membraneScrew the membrane onto the probe. 5. Let stabilizeTurn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)6. AdjustPush down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100. You are now calibrated. Extra tips Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane. Always use fresh electrolyte solution (MA9071).