SKU/Artículo: AMZ-B0CHJL7NM2

Hiletgo

HiLetgo 2pcs 5A AC Current Sensor Current Detection Sensor Relay 12V AC Current Relay Module AC Sensor AC Current Relay Switch with Over Current Protection

Style:

12V

Disponibilidad:
En stock
Peso con empaque:
0.33 kg
Devolución:
Condición
Nuevo
Producto de:
Amazon

Sobre este producto
  • 5A AC Current Sensor Current Detection Sensor
  • AC Current Relay Switch, 5V 12V 24V Optional
  • Current detection resolution can change the parameter of resistance parameters
  • Over-current signal setting critical point adjustable, the current detection range AC0.3A-5A
AR$27,598
31% OFF
AR$19,028

IMPORT EASILY

By purchasing this product you can deduct VAT with your RUT number

AR$27,598
31% OFF
AR$19,028

Pagá fácil y rápido con Mercado Pago o MODO

Llega en 8 a 12 días hábiles
con envío
Tienes garantía de entrega
Este producto viaja de USA a tus manos en
Medios de pago Tarjetas de Crédito y Débito

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

Specifications: Working voltage: DC5V/12V/24V Working current: Frequency range: 20Hz-400Hz Output mode: switching signal output Humidity: 0-95% RH Size: 4.4x3.8cm/1.73x1.5" Interfaces: VCC: Positive; GND: Negative; NO: Normally open, NO and COM are disconnected before the relay is closed, and short circuit after the relay is closed COM: common, relay common interface; NC: Normally closed, NC and COM are shorted before the relay is closed, and disconnected after the relay is closed Instructions: 5A Over-current protection Sensor moduleuses current transformer to collect the AC signal to achieve the relay over-current signal output within 0-5A. Relay pull while over-current, relay released while not over-current. Users can use the relay COM, NC, NO three ports to control the external circuit on and off, in order to achieve over-current protection. Use the potentiometer to set the overcurrent protection point, the clockwise adjustment reduces the detection current. 1. Measured the wire through the current transformer, connect VCC and GND to DC12V power supply. 2. Adjust the potentiometer, when you hear the sound of the relay pull (can be measured with a multimeter COM and NO whether was turned on, if connected to the relay means activated), then reduce or cut off the current flowing that through the tested wire , if the relay release at this time that over-current protection point has been identified (available to multimeter COM and NC measurement whether is connected, if connected to the relay means been released). 3. When reduce or cut off the current flowing through the wire , the relay is not released, will still need to continue to adjust the potentiometer to find the over-current protection point. Package included: 2 x AC Current Sensor Relay Modules (5V 12V 24V Optional, you will get the two SAME ones, not mixed types.)