DC 12V-24V Pulse Trigger Cycle Delay Timer Switch ON/Off Relay Control Module MOS Control Board LED Display
En stock
0.15 kg
Sí
Nuevo
Amazon
USA
- Specification: 2: Trigger Source: Active-high (3.0V-24V), have optocoupler isolation, can improve the system's anti-jamming capability (customers can also shorting common ground). Output capacity: 5V--36V DC, 15A continuous current at room temperature, 400W power (maximum current up to 30A under auxiliary cooling conditions) Service life: infinite times switch Working temperature: - 40~85℃ Weight: Approx.16g/0.6oz Operating mode: P1: trigger signal, the relay is on "OP" time, and then disconnect; in the "OP" time, as follows: P1.1: is triggered again, invalid P1.2: is triggered again, the clock is reset P1.3: trigger again, relay off, stop the clock; P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and then disconnect relay; P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off "CL" time, then the cycle, if the trigger period, the relay off, stop the clock; the number of cycles ( "LOP ") can be set. P3.2: without triggering signal, the relay is on "OP" time, the relay off "CL" time, and has been cycling; frequency ( "LOP") cycle can be set; P-4: holding function. If there is a trigger timing is cleared, the relay remains on; when the disappears, after the timing "OP" time, the relay is; if another during timing, timing is cleared; Pay attention: 1. The module is an active output, the output voltage equal to the input voltage. 2.'DC + 'and' load + 'This is an internal short circuit of the poles, but' DC- 'and' load - 'poles during use can not be shorted, otherwise the load can not be controlled on and off, which is equivalent load is been carrying electricity. Package list: 1 x Pulse Cycle Delay Timer Switch
IMPORT EASILY
By purchasing this product you can deduct VAT with your RUT number
Conoce más detalles
✔ UPGRADE ALGORITHM -- 16 opto isolated digital inputs,3 opto isolated digital outputs; Upgrade algorithm,support soft interpolation,fixed arc interpolation of the old version. ✔ CLEAR SIMPLE INTERFACE -- Analog spindle control 0-10V spindle control (can be modified as PWM output); Interface clear and simple, powerful, almost meet all requirements. ✔ EMERGENCY STOP KEY -- There is a key emergency STOP function (STOP key), with reverse connection protection, reverse connection does not burn. Added sleep mode, after enabling, 5 minutes without any operation, automatically close the display, any button to wake up. ✔ ADJUSTABLE PARAMETERS -- Different OP, CL and LOP parameters can be set, which are independent and saved separately. Set parameters for automatic power off and save. ✔ ANTI-INTERFERENCE ABILITY -- With optocoupler isolation, enhance anti-interference ability, industrial level circuit board, set parameters after power off forever memory.