Sobre este producto
  • Product information Product name: High-power 50W motor forward and reverse controller Product size: 60x34x12mm, opening size 53.9x28.6mm Product weight: net weight 17.2g, including packaging 18.4g Product power consumption: 18mA Time range: 0.01 seconds-999 minutes, adjustable at any time Speed ​​range: 1-100 Input voltage range: DC3.3-15V Output capacity: maximum output current 4.2A, maximum power 60W Signal type: switch button, dry node, NPN sensor low-level signal Ambient temperature: -20~50 degrees Applicable motor: DC brushed motor, push rod motor, motor within 50W Product features: input optocoupler isolation, no noise, 0.01 second fast switching, stepless speed change With overcurrent protection. Can control the forward and reverse rotation of DC motors, speed regulation, fixed speed, limit multi-function Integrated to meet more application needs Product function introduction Key operation mode POO: Press the UP key to run forward, press the UP key or STOP key again to stop. Press the DOWN key to run reversely, press the DOWN key or STOP key again to stop P01: Press the UP key without releasing it to run forward, and release it to stop. Press the DOWN key without releasing it to run reversely, and release it to stop Power-on operation mode: No trigger required Power-on operation, no trigger required, the trigger end can be connected to the limit switch, and the movement stops after triggering P10: After the module is powered on, it keeps running forward, and the limit switch stops P11: After the module is powered on, the forward time A stops P12: After the module is powered on, the forward time A, the delay time b, the cycle LOP times stop P13: After the module is powered on, the forward time A, the delay time b, the reverse time C, stop P14: After the module is powered on, the delay time b, the reverse time C, the delay time d. Reverse time C, delay time d, stop after LOP cycles P15: After the module is powered on, forward time A, delay time b, reverse time C, delay time d. Stop after LOP cycles Modes to be triggered P20: Give a signal, the motor rotates forward, the signal triggers, and the motor stops P21: Give a signal, the motor rotates forward, and then give a signal, the motor stops P22: Give a signal, the motor stops automatically after A seconds of forward rotation P23: Give a signal, the motor stops automatically after A seconds of forward rotation. The signal disappears, and the reverse rotation stops for C seconds P24: Give a signal, the motor stops automatically after A seconds of forward rotation. Give a signal again, and the motor stops automatically after C seconds of reverse rotation P25: There is a signal, no action, the signal disappears, forward rotation A, stop b, reverse rotation C stop P26: Give a signal, forward rotation time A, delay time b, stop after LOP cycles P27: Give a signal, forward rotation time A, delay time b, reverse rotation time C, stop. Give the signal again and repeat the execution once P28: Give the signal, delay time b, reverse time C, delay time d. Reverse time C, delay time d, stop after LOP times of cycle P29: Give the signal, forward time A, delay time b, reverse time C, delay time d. Stop after LOP times of cycle Timing range time unit decimal point description Timing range 0.01 seconds-999 minutes any time can be adjusted Time unit decimal point description After setting the parameter value in the mode selection interface, press the STOP key to select the time unit XXX. Decimal point in the ones place, timing range: 1 second to 999 seconds XX.× decimal point in the tens place, timing range: 0.1 seconds to 99.9 seconds X.XX decimal point in the hundreds place, timing range: 0.01 seconds to 9.99 seconds X.X.X. decimal point is fully lit, timing range: 1 minute to 999 minutes Instructions for key setting operation In the main operation interface, in non-key operation mode, short press UP to increase the speed, short press DOWN key to decrease the speed Press and hold the SET button for 2 seconds and release it on the main interface to enter the mode selection interface. Press the UP and DOWN buttons to select the mode to be set (P00~P29). After selecting the mode to be set (for example, P03), press the SET button to set the corresponding parameters. The parameters to be set will flash (A forward time, b delay time, C reverse time) d delay time, LOP cycle times (""---"" represents infinite cycles). Use UP and DOWN to adjust the parameter value. Long press (quick increase or decrease) and short press (increase or decrease 1 unit) are supported. After setting the parameter value, press the STOP button to select the decimal point position and the timing range (the corresponding time is 0.01 seconds to 999 minutes). Press the SET button to set the next parameter of the current mode. The process is the same as above. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and release it. The currently set mode will flash, and then return to the main interface. The parameter setting is successful. It is very simple! In the main operation interface, short press the SET button to enter the speed setting interface. SP is displayed, and after flashing twice, the current speed is displayed. The speed range is 1-100. The parameter value can be adjusted through UP and DOWN. Long press (rapid increase or decrease) and short press (increase or decrease by 1 unit) are supported. After setting, short press the SET button to exit. Screen off and timed shutdown In the main operation interface, long press the STOP button to enter the screen off and timed shutdown settings. SL is displayed, and after flashing twice, the screen off time (1-999 minutes) is displayed. 0 is displayed---, indicating no screen off and untimed shutdown. Adjust the parameter value through UP and DOWN. Long press (rapid increase or decrease) and short press (increase or decrease by 1 unit) are supported. Short press the SET button again, CL is displayed, and flashes twice to set the shutdown time. Adjust the parameter value through UP and DOWN. Long press the STOP button to exit and return to the main interface "

Sin stock

Seleccione otra opción o busque otro producto.

Este producto viaja de USA a tus manos en

Conoce más detalles

DC motor controller parameters: Voltage: DC 3.3V-15V; Current: 5A; Power: 50W; Ambient temperature: -20-50 degrees; Signal type: switch button, dry node, NPN sensor low-level signal Time range: Delay relay 0.01 seconds-999 minutes arbitrarily adjustable 18 functions: This module has 18 common functions to meet more application needs Applicable motors: DC brushed motors, push rod motors, motors within 50W. Product features: Input optocoupler isolation, no noise, 0.01 second fast switching, infinitely variable speed,With overcurrent protection. Can control DC motor forward and reverse, speed regulation, fixed speed, limit multi-function Integrated to meet more application needs.